Abcs Of Fire Sprinkler Hydraulic Calculations

By Young Lindsay


Many types of sprinklers that can be classified according to its activation temperature, fast opening, orifice size of sprinkler discharge or flow rate, type of fuse element, jet application form, coverage area waterjet among many other factors involved in risk analysis and project design by the specialist (fire sprinkler hydraulic calculations).

Automatic sprinklers have an outlet for releasing water, a firing mechanism and a deflector to convert the output stream in a spray of water in area where there is fire. The trigger sprayer can be done by two mechanisms: a thermo-sensitive element or a flame detector. In this type of sprayer, the jet has a stopper that prevents the leakage of water and a stopper device releasing the trigger mechanism in this case is a device for releasing the plug.

There are other automatic, instead of the capsule are connected to a fire detector which sends an automatic valve that opens when the detector knows of a fire. When quenched, the switch closes the valve and, if applicable, would open again if the fire is revived. Systems differ from sprinklers sprayed water on the element that disperses the water these last is a mouthpiece designed to offer an angle of fog.

Fuse trip. The plug is held in position by a mechanism formed by two metal plates joined with a weld, with a melting point of carefully calibrated. In a blaze, the heat generated softens the solder, causing the water pressure acting on the cap and then disarm the system to skip the plug, allowing the escape of liquid. The water goes through the hole and strikes against a sheet, designed to distribute the jet way to rain (deflector). Each spray has its own fuse, so that only those sprinklers that are in zone of influence of trigger.

Therefore, in case of fire, after the destruction of temperature sensor, the lid remains tightly spray glued to the hull and the water from the system is not received. Such cases were reported in the fire at many places in USA. After that, the producers was conducted large-scale action to recall and replace all sprinklers with rubber sealing rings. In some countries the use of sprinklers with a rubber seal is prohibited.

These processes may take more or less depending on rate of release of surrounding heat to spray, the distance between the sprinkler and ceiling, the distance between the spray and the floor, the roof slope and other factors that have been extensively studied by the NFPA (National Fire Protection Association), UL (Underwriters Laboratories), FM (Factory Mutual), among other research and development in flame protection systems.

Another way to activate a sprinkler is associated with flame detector which opens the closed spray, which in this case is a solenoid valve (solenoid valve) when a flame occurs in area protected by the sprinkler. The advantage of this system is that, once the blaze is out, the water outlet is cut and, if reignite, reopens. With the system of sensitive element, it would take someone off the water supply or water damage could exceed those caused by the inferno.

Triggered sprinkler repair and re-use are not subject. They must be replaced with new sprinklers. Temperature rating of sprinklers can be identified by the color of bulb. Before replacing the installed sprinkler-fire extinguishing system must be disconnected completely relieve pressure in piping, drain systems for wet or dry pipe bled for. Followed to dismantle the old sprinklers and install a new one, making sure that its design, temperature and operating time correspond to those indicated in project. After replacing the sprinklers should be installed fire-extinguishing system in standby mode.